Tested and certified CEMS solution


The T100 Compact Marine CEMS is a SO2/CO2 & NOx continuous emission monitoring system, jointly developed by Teledyne-API USA and Instrumatic Denmark.

Plug & Play Solution

The Plug & Play solution is based on a Teledyne-API T100 UV- Fluorescent SO2 analyzer with a NDIR CO2 sensor and Instrumatic’s OXYDAN Exhaust gas dilution probe. The CEM system is tested and ready for use, fits the standard IMO flange and only needs to be connected to power, instrument air, and signal/communication cables.

A fully autonomous system – automatic calibration of the entire system from the probe tip to the output – self-diagnostic – integrated in one cabinet, with one umbilical cord directly from the sensor cabinet to the sampling probe.

Tested & Verified

Wear and tear are at the absolute minimum, and no contamination of the system occurs due to the sample handling method that provides a nearly ambient level of the gas sample, without any particulates, sod, etc.

Facts about exhaust gas sampling.

The T100 SO2/CO2 & NOx Compact Marine CEMS has been tested and verified by FORCE Technology testing institute (Denmark) to be in compliance with the IMO MARPOL ANNEX VI regulations MEPC.259 (68) & MEPC.177 (58) and has been approved by ABS.

Lowest cost of ownership – long service intervals – no electrical pumps / no moving parts!

Additional certifications:
The T100 SO2 analyzer is used worldwide and holds the following ambient air quality monitoring certifications:
US EPA: EQSA-0495-100
EU: EN14212 TÜV Rheinland
QAL1 Certified: EN15267
MCerts: Sira MC0500067/07

CNEMC: ()No. 2015-028 Report